EnP73220ukUPS Uninterruptible Power SupplyUser ManualP73220uk_Gold_UPSMan 27-05-2002 15:01 Page 1
Installation (continued)OperationCAUTION: This surge protection device is for indoor use only. Never install telephonewiring during a lightning storm.
Alarm11Software Options8.0 Belkin Sentry Bulldog Shutdown Management Software Belkin Sentry Bulldog Shutdown Management Software receives communicatio
Software Options (continued)128.2 USB (Universal Serial Bus): HID (Human Interface Device) setup procedure8.2.1 When the USB cable that comes with the
USB Interface Port (continued)131. Firmware ...Version Of Firmware2. Rating VA...Ra
RS232 Interface Port14RS232 Pin definition:NC ...1 6 ...NCTXD...2 7 ...NCRXD ...
Battery Replacement15The average life of a battery is 3-5 years before ever needing to be replaced.11.0 EcoBattery Replacement ProgramIn the event tha
Battery Replacement (continued)Refer Servicing to qualified service personnel or contact Belkin Components.Diagram aDiagram bSlide the batterycompartm
TroubleshootingStorage17PROBLEM POSSIBLE CAUSE SOLUTIONOn/off/test/button notpushed or pushed less than 3 secondsBattery voltage less than10VUPS fault
Specifications (RS232 Series)18INPUT Capacity 325VA(211W) 425VA(255W) 525VA(315W) 625VA(375W)Voltage 187 Vac - 280 VacFrequency 50Hz or 60Hz ±3Hz (aut
Specifications (USB Series)19INPUT Capacity 350VA(227W) 500VA(300W) 650VA(390W)Voltage 187 Vac - 280 VacFrequency 50Hz or 60Hz ±3Hz (auto sensing)OUTP
Important Safety Instructions2Thank you for purchasing the Belkin Uninterruptible Power Supply (UPS). It will provide you with the best protection for
InformationCE Declaration of ConformityWe, Belkin Components, declare under our sole responsibility that the F6C350-USB/F6C500-USB/F6C650-USB/ F6C325-
Table of Contents3Section Page1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction4Have you ever noticed your lights dim or flicker when you turn on your dishwasher or air-conditioning? This common occurrence is attribut
Safety5CAUTION!• To reduce the risk of electric shock, disconnect the UPS from the main power supply beforeinstalling a computer interface signal cab
Presentation6LED: Light: FlashMEANING4.0 ON LINEGreenUtility is normal.Utility is abnormal—AVR (Automatic VoltageRegulation) in operation.4.1 ON BA
Presentation (continued)7REAR PANEL4.5 INTERFACE PORTProvides both USB or RS232 (Depending on model) to relay the signal to support DO
Presentation (continued)4.11 Surge-OnlyProtected outlets4.10 Battery Back-up outlets4.5 Interface PortUSB or RS232 (Depending on model)4.6 Telep
Installation9a5.0 InspectionInspect the UPS upon receipt. The packaging is recyclable; save it for reuse or dispose of it properly.5.1 Placement Insta