Belkin Power Management Software Uninterruptible Power Supply Software User’s Manual For Microsoft Windows 98 Microsoft Windows NT Microsoft Windows
Belkin Power Management Software 1.1. Packing including ♦ One Belkin Power Management Software software CD ♦ One Belkin Power Management Software cabl
Belkin Power Management Software 2. Hardware Installation Please go by the following steps: a. Connect the Serial/USB cable to the battery backup’s
Belkin Power Management Software 1) When connect USB cable to a computer with Window 98 system at the first time, it will appears the follow window.
Belkin Power Management Software 3) Please set the USB driver location to start search 4) Windows has found the USB driver, please click “Next” to
Belkin Power Management Software 5) Windows has finished installing the USB driver. 6) Once after execute the above installing procedures, please ma
Belkin Power Management Software WARNING Belkin Power Management Software cable is specially design, Do not use any other CABLES to connect UPS. W
Belkin Power Management Software 3. Belkin Power Management Software for Windows 3.1. Features ♦ Support Windows NT Service function. ♦ Support mul
Belkin Power Management Software 3.2. Software Installation The SETUP program is required for Belkin Power Management Software installation. After ins
Belkin Power Management Software to ‘control panel->service’ and check if ‘Rupsmon’ service has started. Belkin Power Management Software is operat
Belkin Power Management Software ♦ Belkin Power Management Software Readme:Belkin Power Management Software simple introduction ♦ Belkin Power Manag
Contact Belkin Corporate Headquarters Belkin Corporation 501 West Walnut Street Compton • CA • 90220-5221 • USA Tel: 310.898.1100 Fax: 310.898.1111
Belkin Power Management Software 3.4.1. UPS dynamic display area This area displays some relevant information about the UPS. Users can select differen
Belkin Power Management Software ♦ Monitor Local UPS Select monitor local UPS. ♦ Monitor Remote UPS (1) Select monitor remote UPS. (2) You can mod
Belkin Power Management Software 3.4.3.2. Settings After selecting a UPS, other parameters may be configured on the other Settings dialogue box tabs.
Belkin Power Management Software ♦ Computer Shutdown Sequence Settings: Set the functions you want to execute when the software detects an AC power fa
Belkin Power Management Software A. General Settings ♦ Communication Type: RS232/USB ♦ Select Comm Port: Configure communication port to connect with
Belkin Power Management Software Attention: Belkin Power Management Software will try to close general applications and store files by artificial inte
Belkin Power Management Software C. Broadcast Settings Enable /disable broadcasting warning message when Belkin Power Management Software2000 detects
Belkin Power Management Software ♦ Enable E-Mail: In this configuration, the messages could be sent to the administrator by e-mail. Shown as below.
Belkin Power Management Software Server Require Authentication: Some Email Server required authentication by password, user can set the password her
Belkin Power Management Software For sending all events to the same email account, select “All Events” and type the receiving email address. Fol
France Belkin SAS Components 5 rue du Petit Robinson 78 350 Jouy en Josas • France Tel: +33 (0) 1 34 58 14 00 Fax: +33 (0) 1 39 46 62 89 European Cu
Belkin Power Management Software ♦ Enable Pager: In this function, the users can set the messages to the system administrator by pager. The configura
Belkin Power Management Software Send Notification to the same pager number:Select this check box to send all messages to the same pager and enter
Belkin Power Management Software ♦ Time Needed for Shutdown Sequence Before UPS Turn Off: Set time interval from when Windows shutdown to UPS power s
Belkin Power Management Software ♦ Actions .Turn on UPS .Shutdown Operating System and UPS .UPS Self-Test Until Battery Low .UPS Self-Test for 10 Se
Belkin Power Management Software "Schedule" screen, then the new schedule could be seen in the record. If you want to set more records, repe
Belkin Power Management Software 3.4.3.4. Data Log The UPS data could be recorded in this section, such as the input and output voltage, line frequenc
Belkin Power Management Software 3.4.3.5. Event Log You can check the date, time, and description of events in Event Log. The maximum number of data c
Belkin Power Management Software 3.4.3.6. History Calendar In this section, you can check the monthly event, including AC fail, battery low, OS and UP
Belkin Power Management Software 3.4.3.7. Control Command UPS directly for the following test. ♦ UPS Self-Test for 10 Secs ♦ UPS Self-Test Until Ba
Belkin Power Management Software 3.4.3.8. Closed Files Record In this section, you can check the closed applications and saved files. Method: select
Fax: +31 (0) 20 654 7349 European Customer Service/Sales: 00 800 223 55 460 [email protected] European Tech Support: 00 800 223 55 460 eurosupp
Belkin Power Management Software 3.4.3.9. About Belkin Power Management Software Clicking on "About" in the Belkin Power Management Softwar
Belkin Power Management Software 4. Belkin Power Management Software for Linux, FreeBSD 4.1. Features Power Crisis Management ♦ Utility Failure an
Belkin Power Management Software POWER MANAGEMENT UTILITIES ♦ Automatic installation procedure. ♦ Automatic background process initialization on start
Belkin Power Management Software 4.2. Software Installation 1. Log in as the super-user. 2. Insert Belkin Power Management Software for Unix CD in CD-
Belkin Power Management Software 4.Select the target system from the menu. Installation program will automatically copy files to the default location:
Belkin Power Management Software 6.After configuration, press [q]. The installation program will launch the Belkin Power Management Software for Uni
Belkin Power Management Software 4.3. Configuration 4.3.1. Configure Belkin Power Management Software for Unix Before using Belkin Power Management S
Belkin Power Management Software Detailed Description of Each Option : [d] System Shutdown Delay Time When AC Power Failed: This is the allotted
Belkin Power Management Software [k] <<Change UPS Monitoring>> Set this value to Monitor UPS from local serial port if the UPS providing
Belkin Power Management Software [a] Turn off UPS after System Shutdown Set this value to YES if you want Belkin Power Management Software to turn off
Singapore Belkin Pte Limited 9 Temasek Boulevard #27-01 Suntec Tower 2 Singapore 038989 Tel.: +65 6485 7620 Fax: +65 6485 7649 www.belkin.com Tech S
Belkin Power Management Software [c] Communication Port: This is the device name of the serial port connected to the UPS. The default port name shou
Belkin Power Management Software For Linux OS, check the file ‘/etc/inittab’ for the line below, and change ”respawn” to ”off”: ttya:2345:respawn:/sb
Belkin Power Management Software 4.3.4. Event Notice by Email Belkin Power Management Software for Unix provides event notice functions. These functi
Belkin Power Management Software when utility recover, line(s) between the third and the fourth lines with a '~' mark leading to denote the
Belkin Power Management Software 4.3.6. Shutdown Batch Job Belkin Power Management Software for Unix provides a batch job function. This function enab
Belkin Power Management Software 4.4. Using Belkin Power Management Software for Unix 4.4.1. Using the "Belkin Power Management Software"
Belkin Power Management Software Monitor the UPS status: /etc/belkin/belkin status (see 4.5.5) Send Commands Directly to the UPS /etc/belkin/be
Belkin Power Management Software program option would appear on the screen. 4.4.2. Uninstall Belkin Power Management Software for Unix Follow these st
Belkin Power Management Software 4.5. Monitor the UPS Status The Belkin Power Management Software Status screen provides a visual status-check of imp
Belkin Power Management Software 2. Press <enter>. Belkin Power Management Software Status checks the configuration settings This screen appe
Belkin Power Management Software SIMPLE INSTALLATION Windows 98, NT, 2000, Me, XP,2003 ♦ Hardware Installation a. Connect the Serial/USB cable to t
Belkin Power Management Software This screen appears if you configured Belkin Power Management Software to monitor the UPS through a local SNMP Agen
Belkin Power Management Software To monitor a remote UPS 1. Type “/etc/belkin/belkin status” to bring up the initial select screen. 2. Press [r].
Belkin Power Management Software Press [m] to see more information such as system contact, system name and system location. Press [b] to continue vie
Belkin Power Management Software 4.6. Control your UPS Belkin Power Management Software for Unix gives you the ability to shut down, restart, initiat
Belkin Power Management Software [n] Shut Down UPS UPS stops providing output power after a few seconds. [a] Cancel Shut Down Command Cancel an
Belkin Power Management Software [u] Reboot UPS UPS shuts off then turns back on. [l] Put UPS to Sleep Specify the duration of sleep using [+] a
Belkin Power Management Software 4.8. Files List and CD Contents Operating System File Name Linux Linux.tar.gz FreeBSD Freebsd.tar.gz 4.9.
Belkin Power Management Software 4.10. System Parameters Operating System COM PortShutdown Command Start up file Linux /dev/ttyS0 /sbin/halt /e
Belkin Power Management Software SIMPLE INSTALLATION Linux, FreeBSD ♦ Hardware Installation a. Connect the Serial cabl
Belkin Power Management Software CONTENTS 1. Introduction ......1 1.1. Packing in
Belkin Power Management Software 1. Introduction Belkin Power Management Software is a smart UPS monitoring and controlling software. The software di