Belkin PMS User Manual

Browse online or download User Manual for Power supply units Belkin PMS. Belkin PMS User`s manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 67
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Belkin Power Management Software
Uninterruptible Power Supply
Software
User’s Manual
For
Microsoft Windows 98
Microsoft Windows NT
Microsoft Windows 2000
Microsoft Windows Me
Microsoft Windows XP
Microsoft Windows 2003
Linux, FreeBSD
Page view 0
1 2 3 4 5 6 ... 66 67

Summary of Contents

Page 1 - User’s Manual

Belkin Power Management Software Uninterruptible Power Supply Software User’s Manual For Microsoft Windows 98 Microsoft Windows NT Microsoft Windows

Page 2

Belkin Power Management Software 1.1. Packing including ♦ One Belkin Power Management Software software CD ♦ One Belkin Power Management Software cabl

Page 3

Belkin Power Management Software 2. Hardware Installation Please go by the following steps: a. Connect the Serial/USB cable to the battery backup’s

Page 4

Belkin Power Management Software 1) When connect USB cable to a computer with Window 98 system at the first time, it will appears the follow window.

Page 5

Belkin Power Management Software 3) Please set the USB driver location to start search 4) Windows has found the USB driver, please click “Next” to

Page 6

Belkin Power Management Software 5) Windows has finished installing the USB driver. 6) Once after execute the above installing procedures, please ma

Page 7 - ♦ Software Installation

Belkin Power Management Software WARNING  Belkin Power Management Software cable is specially design, Do not use any other CABLES to connect UPS.  W

Page 8 - CONTENTS

Belkin Power Management Software 3. Belkin Power Management Software for Windows 3.1. Features ♦ Support Windows NT Service function. ♦ Support mul

Page 9 - Introduction

Belkin Power Management Software 3.2. Software Installation The SETUP program is required for Belkin Power Management Software installation. After ins

Page 10

Belkin Power Management Software to ‘control panel->service’ and check if ‘Rupsmon’ service has started. Belkin Power Management Software is operat

Page 11 - Hardware Installation

Belkin Power Management Software ♦ Belkin Power Management Software Readme:Belkin Power Management Software simple introduction ♦ Belkin Power Manag

Page 12

Contact Belkin Corporate Headquarters Belkin Corporation 501 West Walnut Street Compton • CA • 90220-5221 • USA Tel: 310.898.1100 Fax: 310.898.1111

Page 13

Belkin Power Management Software 3.4.1. UPS dynamic display area This area displays some relevant information about the UPS. Users can select differen

Page 14

Belkin Power Management Software ♦ Monitor Local UPS Select monitor local UPS. ♦ Monitor Remote UPS (1) Select monitor remote UPS. (2) You can mod

Page 15 - WARNING

Belkin Power Management Software 3.4.3.2. Settings After selecting a UPS, other parameters may be configured on the other Settings dialogue box tabs.

Page 16

Belkin Power Management Software ♦ Computer Shutdown Sequence Settings: Set the functions you want to execute when the software detects an AC power fa

Page 17

Belkin Power Management Software A. General Settings ♦ Communication Type: RS232/USB ♦ Select Comm Port: Configure communication port to connect with

Page 18

Belkin Power Management Software Attention: Belkin Power Management Software will try to close general applications and store files by artificial inte

Page 19

Belkin Power Management Software C. Broadcast Settings Enable /disable broadcasting warning message when Belkin Power Management Software2000 detects

Page 20

Belkin Power Management Software ♦ Enable E-Mail: In this configuration, the messages could be sent to the administrator by e-mail. Shown as below. 

Page 21

Belkin Power Management Software  Server Require Authentication: Some Email Server required authentication by password, user can set the password her

Page 22

Belkin Power Management Software  For sending all events to the same email account, select “All Events” and type the receiving email address.  Fol

Page 23

France Belkin SAS Components 5 rue du Petit Robinson 78 350 Jouy en Josas • France Tel: +33 (0) 1 34 58 14 00 Fax: +33 (0) 1 39 46 62 89 European Cu

Page 24

Belkin Power Management Software ♦ Enable Pager: In this function, the users can set the messages to the system administrator by pager. The configura

Page 25

Belkin Power Management Software  Send Notification to the same pager number:Select this check box to send all messages to the same pager and enter

Page 26

Belkin Power Management Software ♦ Time Needed for Shutdown Sequence Before UPS Turn Off: Set time interval from when Windows shutdown to UPS power s

Page 27

Belkin Power Management Software ♦ Actions .Turn on UPS .Shutdown Operating System and UPS .UPS Self-Test Until Battery Low .UPS Self-Test for 10 Se

Page 28

Belkin Power Management Software "Schedule" screen, then the new schedule could be seen in the record. If you want to set more records, repe

Page 29

Belkin Power Management Software 3.4.3.4. Data Log The UPS data could be recorded in this section, such as the input and output voltage, line frequenc

Page 30

Belkin Power Management Software 3.4.3.5. Event Log You can check the date, time, and description of events in Event Log. The maximum number of data c

Page 31

Belkin Power Management Software 3.4.3.6. History Calendar In this section, you can check the monthly event, including AC fail, battery low, OS and UP

Page 32

Belkin Power Management Software 3.4.3.7. Control Command UPS directly for the following test. ♦ UPS Self-Test for 10 Secs ♦ UPS Self-Test Until Ba

Page 33

Belkin Power Management Software 3.4.3.8. Closed Files Record In this section, you can check the closed applications and saved files. Method: select

Page 34

Fax: +31 (0) 20 654 7349 European Customer Service/Sales: 00 800 223 55 460 [email protected] European Tech Support: 00 800 223 55 460 eurosupp

Page 35

Belkin Power Management Software 3.4.3.9. About Belkin Power Management Software Clicking on "About" in the Belkin Power Management Softwar

Page 36 - 3.4.3.5. Event Log

Belkin Power Management Software 4. Belkin Power Management Software for Linux, FreeBSD 4.1. Features Power Crisis Management ♦ Utility Failure an

Page 37

Belkin Power Management Software POWER MANAGEMENT UTILITIES ♦ Automatic installation procedure. ♦ Automatic background process initialization on start

Page 38

Belkin Power Management Software 4.2. Software Installation 1. Log in as the super-user. 2. Insert Belkin Power Management Software for Unix CD in CD-

Page 39

Belkin Power Management Software 4.Select the target system from the menu. Installation program will automatically copy files to the default location:

Page 40

Belkin Power Management Software 6.After configuration, press [q]. The installation program will launch the Belkin Power Management Software for Uni

Page 41 - UPS Management

Belkin Power Management Software 4.3. Configuration 4.3.1. Configure Belkin Power Management Software for Unix Before using Belkin Power Management S

Page 42 - POWER MANAGEMENT UTILITIES

Belkin Power Management Software  Detailed Description of Each Option : [d] System Shutdown Delay Time When AC Power Failed: This is the allotted

Page 43 -

Belkin Power Management Software [k] <<Change UPS Monitoring>> Set this value to Monitor UPS from local serial port if the UPS providing

Page 44

Belkin Power Management Software [a] Turn off UPS after System Shutdown Set this value to YES if you want Belkin Power Management Software to turn off

Page 45

Singapore Belkin Pte Limited 9 Temasek Boulevard #27-01 Suntec Tower 2 Singapore 038989 Tel.: +65 6485 7620 Fax: +65 6485 7649 www.belkin.com Tech S

Page 46 - /etc/belkin/belkin config’

Belkin Power Management Software [c] Communication Port: This is the device name of the serial port connected to the UPS. The default port name shou

Page 47

Belkin Power Management Software For Linux OS, check the file ‘/etc/inittab’ for the line below, and change ”respawn” to ”off”: ttya:2345:respawn:/sb

Page 48

Belkin Power Management Software 4.3.4. Event Notice by Email Belkin Power Management Software for Unix provides event notice functions. These functi

Page 49

Belkin Power Management Software when utility recover, line(s) between the third and the fourth lines with a '~' mark leading to denote the

Page 50

Belkin Power Management Software 4.3.6. Shutdown Batch Job Belkin Power Management Software for Unix provides a batch job function. This function enab

Page 51 - Page Ip Address

Belkin Power Management Software 4.4. Using Belkin Power Management Software for Unix 4.4.1. Using the "Belkin Power Management Software"

Page 52

Belkin Power Management Software  Monitor the UPS status: /etc/belkin/belkin status (see 4.5.5)  Send Commands Directly to the UPS /etc/belkin/be

Page 53

Belkin Power Management Software program option would appear on the screen. 4.4.2. Uninstall Belkin Power Management Software for Unix Follow these st

Page 54

Belkin Power Management Software 4.5. Monitor the UPS Status The Belkin Power Management Software Status screen provides a visual status-check of imp

Page 55

Belkin Power Management Software 2. Press <enter>. Belkin Power Management Software Status checks the configuration settings  This screen appe

Page 56

Belkin Power Management Software SIMPLE INSTALLATION Windows 98, NT, 2000, Me, XP,2003 ♦ Hardware Installation a. Connect the Serial/USB cable to t

Page 57 - If your Operating System is:

Belkin Power Management Software  This screen appears if you configured Belkin Power Management Software to monitor the UPS through a local SNMP Agen

Page 58 - To Monitor Your Local UPS

Belkin Power Management Software  To monitor a remote UPS 1. Type “/etc/belkin/belkin status” to bring up the initial select screen. 2. Press [r].

Page 59

Belkin Power Management Software Press [m] to see more information such as system contact, system name and system location. Press [b] to continue vie

Page 60

Belkin Power Management Software 4.6. Control your UPS Belkin Power Management Software for Unix gives you the ability to shut down, restart, initiat

Page 61 - To monitor a remote UPS

Belkin Power Management Software  [n] Shut Down UPS UPS stops providing output power after a few seconds.  [a] Cancel Shut Down Command Cancel an

Page 62

Belkin Power Management Software  [u] Reboot UPS UPS shuts off then turns back on.  [l] Put UPS to Sleep Specify the duration of sleep using [+] a

Page 63

Belkin Power Management Software 4.8. Files List and CD Contents Operating System File Name Linux Linux.tar.gz FreeBSD Freebsd.tar.gz 4.9.

Page 64

Belkin Power Management Software 4.10. System Parameters Operating System COM PortShutdown Command Start up file Linux /dev/ttyS0 /sbin/halt /e

Page 65

Belkin Power Management Software SIMPLE INSTALLATION Linux, FreeBSD ♦ Hardware Installation a. Connect the Serial cabl

Page 66 - Operating

Belkin Power Management Software CONTENTS 1. Introduction ......1 1.1. Packing in

Page 67

Belkin Power Management Software 1. Introduction Belkin Power Management Software is a smart UPS monitoring and controlling software. The software di

Comments to this Manuals

No comments